OPzV Gel Battery with 20+ Years Design Life Female Copper Insert M8 Terminal and ABS Case

Product Details

Place of Origin: Wuhan

Certification: CE UL ISO9001 ISO14001

Model Number: OPzV2-250

Payment & Shipping Terms

Minimum Order Quantity: Negotiable

Price: Negotiable

Packaging Details: Carton and Wooden Pallet

Delivery Time: 30 Days

Payment Terms: T/T L/C,D/A,D/P

Supply Ability: 10000PCS/30Days

Get Best Price
Highlight:

opzv battery

,

tubular gel battery

Type:
Tubular Gel Battery
Nominal Voltage:
2V
Rated Capacity:
500Ah
Battery Case:
ABS
Battery Designed Life:
More Than 20 Years
Approx Weight:
37.3Kg
Terminal Type:
Female Copper Insert M8 (torque:10~12N.m)
Application:
Telecom Outdoor Applications, Renewable Energy Systems And Other Harsh Environment Applications.
Type:
Tubular Gel Battery
Nominal Voltage:
2V
Rated Capacity:
500Ah
Battery Case:
ABS
Battery Designed Life:
More Than 20 Years
Approx Weight:
37.3Kg
Terminal Type:
Female Copper Insert M8 (torque:10~12N.m)
Application:
Telecom Outdoor Applications, Renewable Energy Systems And Other Harsh Environment Applications.
OPzV Gel Battery with 20+ Years Design Life Female Copper Insert M8 Terminal and ABS Case
Easy Operation 2V250Ah OPzV Gel Battery Female Copper Insert M8 Terminal Type
Product Overview
2V250Ah Tubular Gel Battery OPzV Battery Deep Cycle Gel Battery Pure Gel Battery
Product Features
The OPzV series adopts an Immobilized Gel and Tubular Positive Plate technology. It offers high reliability and stable performance. By using die-casted positive grid and patented active material formula, it exceeds the DIN standard values and offers 20+ years design life in float service. It is very suitable for cyclic use under extreme operating conditions.
Construction
  • Positive plate: Tubular plate with die cast Pb-Ca alloy grid
  • Negative plate: Balanced Pb-Ca grid for improved recombination efficiency
  • Separator: Leaf shape polymer separator
  • Electrolyte: Dilute high purity sulphuric acid with fumed Silica gel
  • Battery container and cover: ABS
  • Pillar seal: 100% factory tested, proven two layers epoxy resin seal
  • Relief valve: Complete with integrated flame arrestor
Specifications
Specification Value
Nominal Voltage (V) 2
Designed Floating Life (20°C) 20+ Years
Nominal Capacity (20°C) 500 Ah @ C10 (to 1.80Vpc)
Dimensions L166mm × W206mm × H506mm
Approx. Weight 36.3 kg (80.0 lbs)
Terminal Type Female Copper Insert M8 (torque: 10~12N.m)
Internal Resistance Approx. 0.56mOhm (fully charged @ 25°C)
Max. Charge Current 100 A
Max. Discharge Current (5S) 2000 A
Short Circuit Current 2600 A
Self Discharge Approx. 2% per month @ 20°C
Ambient Temperature Discharge: -40~65°C
Charge: -30~65°C
Storage: -25~45°C
Float Charge Voltage 2.23V @25°C (-3mV/°C/cell)
Equalize Charge Voltage 2.35V @25°C
Container Material ABS (UL94-V0 optional)
Application
Telecom outdoor applications, renewable energy systems, other harsh environment applications.
Advantages
  • 20+ years design life at floating condition
  • Wide operating temperature range from -40°C to 60°C
  • Tubular positive plate with prolonged cycle life
  • Nano Silica gel electrolyte
  • Lead Calcium die cast grid with improved corrosion resistance capability
  • Excellent deep discharge recovery capability

Overall Rating

5.0
Based on 50 reviews for this product

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

M
Mason Gomez
South Africa Jun 23.2026
Our railway signalling depends on these batteries daily and they have never missed a beat. Excellent product and fair pricing.
C
Charlotte Anderson
France Jun 3.2026
Would recommend these to anyone needing dependable OPzV Gel Battery. We use them in our wind farm control system and the performance has been outstanding.
A
Amelia Lee
Argentina May 26.2026
After comparing several suppliers, we chose these and have no regrets. The data center UPS has been running smoothly for 10 months now.