Send Message
Wuhan Future Intepower Co., Ltd.
products
products
Home > products > LiFEPO4 Lithium Ion Battery > Longer Service Life LiFePO4 Lithium Battery Replacement Lead Acid 12V 8Ah

Longer Service Life LiFePO4 Lithium Battery Replacement Lead Acid 12V 8Ah

Product Details

Place of Origin: China

Brand Name: FBATTERY

Certification: CE,UL,ROHS

Model Number: FB-1208

Payment & Shipping Terms

Minimum Order Quantity: Negotiable

Price: Negotiable

Packaging Details: Carton

Delivery Time: 20Days

Payment Terms: L/C, D/A, D/P, T/T in advance

Supply Ability: 10000PCS/30Days

Get Best Price
Highlight:

Lead Acid Battery 12V 8Ah

,

80mΩ Impedance Lead Acid Battery

Rating Voltage:
12V
Capacity:
8Ah
Charge Voltage:
14.6V±0.05V
Impedance:
80mΩ
Size:
L*W*H=151*65*93mm
Operating Temperature:
Charging 0~45℃
Storage Temperature:
-10℃-40℃ Recommend(25±5℃)
Weight Approx:
0.95kg
Rating Voltage:
12V
Capacity:
8Ah
Charge Voltage:
14.6V±0.05V
Impedance:
80mΩ
Size:
L*W*H=151*65*93mm
Operating Temperature:
Charging 0~45℃
Storage Temperature:
-10℃-40℃ Recommend(25±5℃)
Weight Approx:
0.95kg
Longer Service Life LiFePO4 Lithium Battery Replacement Lead Acid 12V 8Ah
Longer Service Life LiFePO4 Lithium Battery Replacement Lead Acid 12V 8Ah

 

Specification

 

No  Item  Parameter  Remark 
1

Rating Voltage

12V  
2

Capacity

8

1C discharge after full charge.

 

Minimum Capacity

8.1Ah
3

Charge Voltage

14.6V±0.05V  
4

Impedance

80mΩ  
5

Charging Mode

C.C/C.V

Constant Current

/Constant Voltage

6

Charging Metho

Standard Charging

Charging Current2A

Fast Charging

Charging Current 5A

7

Charging Time

Standard Charging

5.5 Hours  

Fast Charging

2.4Hours
9

Overcharge Voltage

3.65±0.05V  
10

Over Discharge Cut Off Voltage

2.2V±0.1V  
11

Over Current

25-40A  
12

Short Circuit

   
13

Operating Consumption Current

50uA(MAX)  
14

Operating Temperature

Charging

0~45℃  

Discharging

-10~60℃
15

Storage Temperature

-10℃-40℃

Recommend(25±5℃)

Storage capacity should be 40%~50% full charge capacity

16

NTC Resistor

NTC

/  
17

ESD Test

±4KV  
18

Discharge Current

≤10A  
19

 Factory Voltage

12.8-13.6V

The open circuit state

20

Weight approx 

0.95kg  
 

 

Storage 

The battery storage shall be in the clean and dry ventilation room at the temperature of -5~35℃ and shall keep out of fire or heat and avoid touching corrosion elements. The batteries shall be charged every 3months during storage. Both the stored cells in the process of the battery and the batteries in delivery shall be “first come, first use”. The battery storage period is 24 months when into the warehouse. Batteries expired must have a thorough check. Only the applicable batteries can be dispatched to the purchaser; the inapplicable ones shall be rechecked, if it remains, the purchaser shall have the right to dispose bad ones.