Product Details
Place of Origin: China
Brand Name: FBATTERY
Certification: CE,UL,ROHS
Model Number: FB-1280
Payment & Shipping Terms
Minimum Order Quantity: Negotiable
Price: Negotiable
Packaging Details: Carton
Delivery Time: 20Days
Payment Terms: L/C,D/A,D/P,T/T in advance
Supply Ability: 10000PCS/30Days
Cell Type: |
LiFePO₄ |
Rating Voltage: |
12V |
Capacity: |
80Ah |
Charge Voltage: |
14.6V±0.05V |
Impedance: |
15mΩ(Max) |
Size: |
L*W*H=260*167*210mm |
Operating Temperature: |
Charging 0~45℃ |
Storage Temperature: |
-10℃-40℃ Recommend(25±5℃) |
Weight Approx: |
8.6kg |
Cell Type: |
LiFePO₄ |
Rating Voltage: |
12V |
Capacity: |
80Ah |
Charge Voltage: |
14.6V±0.05V |
Impedance: |
15mΩ(Max) |
Size: |
L*W*H=260*167*210mm |
Operating Temperature: |
Charging 0~45℃ |
Storage Temperature: |
-10℃-40℃ Recommend(25±5℃) |
Weight Approx: |
8.6kg |
| No | Item | Parameter | Remark |
|---|---|---|---|
| 1 | Rating Voltage | 12.8V | |
| 2 | Capacity | 80Ah | 0.5C discharge after full charge |
| Minimum Capacity | 78AH | ||
| 3 | Charge Voltage | 14.6V±0.05V | |
| 4 | Impedance | 15mΩ(Max) | |
| 5 | Charging Mode | C.C/C.V. | Constant Current / Constant Voltage |
| 6 | Charging Method | Standard Charging | Charging Current 12A |
| Fast Charging | Charging Current 40A | ||
| 7 | Charging Time | Standard Charging | 7.5 Hours |
| Fast Charging | 2.6 Hours | ||
| 9 | Overcharge Voltage | 3.65±0.05V | |
| 10 | Over Discharge Cut Off Voltage | 2.2V±0.1V | |
| 11 | Over Current | 200-300A | |
| 12 | Short Circuit | ||
| 13 | Operating Consumption Current | 50uA(MAX) | |
| 14 | Operating Temperature | Charging: 0~45℃ Discharging: -10~60℃ |
|
| 15 | Storage Temperature | -10℃-40℃ Recommend(25±5℃) | Storage capacity should be 40%~50% full charge capacity |
| 16 | NTC Resistor | / | |
| 17 | ESD Test | ±4KV | |
| 18 | Discharge current | ≤80A | |
| 19 | The factory voltage | 12.8-13.6V | The open circuit state |
| 20 | Weight Approx | 8.6KG |
The battery storage shall be in a clean, dry, and well-ventilated room at temperatures between -5℃ to 35℃. Keep batteries away from fire, heat sources, and corrosive elements.
Batteries should be charged every 3 months during storage. Follow the "first come, first use" principle for both stored cells in process and batteries in delivery.
The battery storage period is 24 months from warehouse entry. Batteries exceeding this period must undergo thorough inspection. Only applicable batteries can be dispatched to purchasers; inapplicable units shall be rechecked, and purchasers retain the right to dispose of defective batteries.