Highlight:

Lead Acid Battery 12V 230Ah

,

CV Mode Lead Acid Battery

Rating Voltage:
12.8V
Capacity:
230Ah
Charge Voltage:
14.6V±0.05V
Impedance:
10mΩ(Max)
Size:
L*W*H=490*171*240mm
Operating Temperature:
Charging 0~45℃
Storage Temperature:
-10℃-40℃ Recommend(25±5℃)
Weight Approx:
20.8kg
Rating Voltage:
12.8V
Capacity:
230Ah
Charge Voltage:
14.6V±0.05V
Impedance:
10mΩ(Max)
Size:
L*W*H=490*171*240mm
Operating Temperature:
Charging 0~45℃
Storage Temperature:
-10℃-40℃ Recommend(25±5℃)
Weight Approx:
20.8kg
Lengthy Charge Time LiFePO4 Lithium Battery Replacement Lead Acid 12V 230Ah
Lengthy Charge Time LiFePO4 Lithium Battery Replacement Lead Acid 12V 230Ah

 

Specification

 

No Item Parameter Remark 
1

Rating Voltage

12.8V 
2

Capacity

230Ah

0.5C discharge after full charge.

Minimum Capacity

220AH
3

Charge Voltage

14.6V±0.05V 
4

Impedance

10mΩ(Max) 
5

Charging Mode

C.C/C.V.

Constant Current
/Constant Voltage

6

Charging Metho
 

Standard Charging

Charging Current30A

Fast Charging

Charging Current 100A

7

Charging Time
 

Standard Charging

8.5Hours 

Fast Charging

2.8Hours
9

Overcharge Voltage

3.65±0.05V 
10

Over Discharge Cut Off Voltage

2.2V±0.1V 
11

Over Current

250-400A 
12

Short Circuit

  
13

Operating Consumption Current

50uA(MAX) 
14

Operating Temperature

Charging

0~45℃ 

Discharging

-10~60℃
15

Storage Temperature

-10℃-40℃
Recommend(25±5℃)

Storage capacity should be 40%~50% full charge capacity

16

NTC Resistor

/ 
17

ESD Test

±4KV 
18

Discharge current

≤200A 
19

The factory voltage

12.8-13.6V

The open circuit state

20Weight Approx 20.8KG 
 
 
 

 
Storage 
 
The battery storage shall be in the clean and dry ventilation room at the temperature of -5~35℃ and shall keep out of fire or heat and avoid touching corrosion elements. The batteries shall be charged every 3months during storage. Both the stored cells in the process of the battery and the batteries in delivery shall be “first come, first use”. The battery storage period is 24 months when into the warehouse. Batteries expired must have a thorough check. Only the applicable batteries can be dispatched to the purchaser; the inapplicable ones shall be rechecked, if it remains, the purchaser shall have the right to dispose bad ones.